I have a PTAC unit in the room above my garage (Amana PTH123A35AC) that I’m trying to connect a thermostat (Honeywell 50018270-001) to. These are my current connections:
PTAC | Thermostat |
---|---|
B | B |
C | C |
GL | G |
R | R |
W2 | W |
Y/W1 | Y |
GH | Unused |
Unused | O |
Unused | Rc |
The only thing that’s not working is the cool setting. Heat and the fan are working fine. I have tried connecting R to Rc and B to O, but neither worked. I’m fairly certain I have something incorrectly wired here, but I’m just not sure which connection.
PTAC Serial Number Decoded:
- PTH: Standard Heat Pump PTHP
- 12: 12,000 BTU/h, 60Hz
- 3: 230/208V, 60Hz, 1 Phase
- A: First Design Series
- 35: 3.5 kW (230/208V)
- AC: Standard Model
Does anyone have any ideas as to why the cool setting isn’t working?
You must log in or register to comment.